Watlow Heater Catalog
Specialty Heaters
FLUENT In-line Heaters Technical Information
Pressure Drop - Water - With Int rnal Baffle
Pressure Drop - Water - With Baffle
1000
14
900
12
800
700
10
600
8
500
6
400
300
Pressure Drop (PSI)
4
Pressure-Drop (mbar)
200
2
100
0
0
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
2.5
Flow (I/min.)
Heater 4.25 in., Fitting 1 / 4 in.
Heater 4.25 in., Fitting 3 / 8 in.
Heater 6.5 in., Fitting 3 / 8 in.
Heater 6.5 in., Fitting 1 / 4 in.
Pressure Drop - Water - Without Baffle
Pressure Drop - Water - Without Internal Baffle
140
2
1.75
120
1.5
100
1.25
80
1
60
0.75
40
Pressure-Drop (mbar)
Pressure Drop (PSI)
0.5
20
0.25
0
0
1
1.25
1.5
1.75
2
2.25
2.5
2.75
3
3.25
3.5
3.75
4
Flow (I/min.)
Heater 4.25 in., Fitting 1 / 4 in.
Heater 4.25 in., Fitting 3 / 8 in.
Heater 6.5 in., Fitting 3 / 8 in.
Heater 6.5 in., Fitting 1 / 4 in.
Heater internal temperature will vary based on flow rate, heater watt density and presence of the internal baffle, which increases turbulent flow. General guidelines for baffle consideration: • For flow rates below 1 l/min, baffle should always be used to prevent an over-temperature condition. • For flow rates over 1 l/min, removing the baffle is possible but will result in a higher internal temperature.
445