Watlow Heater Catalog
Cartridge/Insertion Heaters
E xtended C apability
Extended Capabilities for High-Temperature (HT) FIREROD ® Heaters Options • Thermocouples • Independently controllable heat zones • Distributed wattage • Flanges
Maximum Allowable Watt Density - Heating Metals
0.100 0.090 0.080 0.070 0.060
• Post terminals • Bent FIREROD
0.050
To consider the HT FIREROD for your application, use the recommended Maximum Watt Density graph shown.
0.040
0.030
1300 ° F 1200 ° F
0.020
1500 ° F
1600 ° F
1400 ° F
Fit in Hole (in.)
0.010 0.009 0.008 0.007
0.006
0.005
30
40
50 60 70 80 90 100
Watt Density—W/in 2
Note: Extended capabilities are subject to a business case review.
34