Watlow Heater Catalog
Immersion Heaters
WATROD ANSI Flange Immersion Heaters
®
®
5"-150# FLANGE Application: Bunker C, Asphalt and #6 Fuel Oil
General Purpose or NEMA 4 Enclosure
①
• 5 inch - 150 lb ANSI flange • WATROD elements • Without thermostat • General purpose or NEMA 4 enclosure
Thermowell
0.475 in. (12.1 mm) Dia. Element
5
4 ¾ in. O.D. (121 mm)
7 in. (178 mm)
4 in. (102 mm) Cold (Ref.) “B”
8 in. O.D. (203 mm)
① The number and size of the conduit opening will comply with the National Electrical Code ® standards.
6"-150# FLANGE
# Circ.
“B” Dim. in. (mm)
Ship Wt. lbs (kg)
Part Number
Part Number
WATCONNECT Part Number
Description Volts kW Ph
①
General Purpose Enclosure
NEMA 4 Enclosure
Type J T/C
Type K T/C
0.475 in. (12.1 mm) Dia. Element
Thermowell
6
240 5.0 3 1 40 1 / 2 (1029) 47 (22) 480 5.0 3 1 40 1 / 2 (1029) 47 (22)
8 W/in 2 3 Steel Flange 6-Steel Elements (1.3 W/cm 2 )
FNS740J12S FNS740J12W C2-50 C2-92 FNS740J13S FNS740J13W C2-43 C2-35 FNS748A12S FNS748A12W C2-50 C2-92 FNS748A13S FNS748A13W C2-43 C2-35 FNS764J12S FNS764J12W C2-50 C2-92 FNS764J13S FNS764J13W C2-43 C2-35 FNS777A12S FNS777A12W C2-50 C2-92 FNS777A13S FNS777A13W C2-43 C2-35 FNS740J12XS FNS740J12XW C2-50 C2-92 FNS740J13XS FNS740J13XW C2-43 C2-35 FNS748A12XS FNS748A12XW C2-50 C2-92 FNS748A13XS FNS748A13XW C2-43 C2-35 FNS764J12XS FNS764J12XW C2-236 C2-214 FNS764J13XS FNS764J13XW C2-43 C2-35 FNS777A12XS FNS777A12XW C2-236 C2-214 FNS777A13XS FNS777A13XW C2-225 C2-226 4 in. (102 mm) Cold (Ref.) “B” 8 in. (203 mm)
5 ⁄ in. O.D. (149.2 mm)
8 in. (203 mm)
240 6.0 3 1 48 480 6.0 3 1 48
(1219) 52 (24) (1219) 52 24)
240 8.0 3 1 64 1 / 2 (1638) 57 (26) 480 8.0 3 1 64 1 / 2 (1638) 57 (26)
240 10.0 3 1 77 480 10.0 3 1 77
(1956) 65 (28) (1956) 65 (28)
240 7.5 3 1 40 1 / 2 (1029) 53 (24) 480 7.5 3 1 40 1 / 2 (1029) 53 (24)
8 W/in 2 3 Steel Flange 9-Steel Elements (1.3 W/cm 2 )
240 9.0 3 1 48 480 9.0 3 1 48
(1219) 60 (28) (1219) 60 (28)
240 12.0 3 1 64 1 / 2 (1638) 68 (31) 480 12.0 3 1 64 1 / 2 (1638) 68 (31)
240 15.0 3 1 77 480 15.0 3 1 77
(1956) 78 (36) (1956) 78 (36)
Notes: • All flange bundles are designed to fit the inside diameter of the equivalent standard schedule pipe • For ANSI flange dimensions, reference chart on page 224 3 Wired for 3-phase operation only