Watlow Heater Catalog
Immersion Heaters
WATROD ANSI Flange Immersion Heaters
®
®
Application: Forced Air and Caustic Solutions
General Purpose
3"-150# FLANGE
¾ in. NPT Knockout ¾ in. NPT Knockout
3"-150# FLANGE
0.475 in. (12.1 mm) Dia. Element 0.475 in. (12.1 mm) Dia. Element
Thermowell
• 3 inch - 150 lb ANSI flange • WATROD elements • Without thermostat • General purpose or NEMA 4 enclosure • Single circuit
4 ⁄ in. (117.5 mm) 4 ⁄ in. (117.5 mm)
1
Thermowell
2 ¾ in. O.D. (70 mm) 2 ¾ in. O.D. (70 mm)
1
4 in. (102 mm) Cold (Ref.)
“B”
3 ⁄ in. Dia. (92.1 mm) 3 ⁄ in. Dia. (92.1 mm)
4 in. (102 mm) Cold (Ref.)
“B”
3"-150# FLANGE
NEMA 4 Enclosure
(2) ¾ in. NPT Hubs (2) ¾ in. NPT Hubs
0.475 in. (12.1 mm) Dia. Element 0.475 in. (12.1 mm) Dia. Element
3"-150# FLANGE
Thermowell
5 ⁄ in. (136.5 mm) 5 ⁄ in. (136.5 mm)
Thermowell
2
2 ¾ in. O.D. (70 mm) 2 ¾ in. O.D. (70 mm)
2
4 in. (102 mm) Cold (Ref.)
3 ⁄ in. Dia. (79.4 mm) 3 ⁄ in. Dia. (79.4 mm)
“B”
4 in. (102 mm) Cold (Ref.)
“B”
WATCONNECT Part Number ¾ in. (19 mm) NPT Knockout ¾ in. (19 mm) NPT Knockout
“B” Dim. in. (mm)
Ship Wt. lbs (kg)
Part Number
Part Number
Description Volts kW Ph
General Purpose Enclosure
NEMA 4 Enclosure
Type J T/C
Type K T/C
23 W/in 2 6 Steel Flange 3-Alloy 800 Elements (3.6 W/cm 2 )
FMNA18A10S FMNA18A10W C1-17 C1-13
240 3.0 1 18 240 3.0 3 18 480 3.0 1 18 480 3.0 3 18 240 4.5 1 25 1 ⁄ 240 4.5 3 25 1 ⁄ 480 4.5 1 25 1 ⁄ 480 4.5 3 25 1 ⁄ 240 6.0 1 33 240 6.0 3 33 480 6.0 1 33 480 6.0 3 33
(457) 23 (11) (457) 23 (11) (457) 23 (11) (457) 23 (11)
FMNA18A3S
FMNA18A3W C2-50 C2-92
FMNA18A11S FMNA18A11W C/F C/F
FMNA18A5S
FMNA18A5W C2-43 C2-35
FMNA25J10S FMNA25J10W C/F C/F
2 (648) 27 (13) 2 (648) 27 (13) 2 (648) 27 (13) 2 (648) 27 (13)
FMNA25J3S
FMNA25J3W C2-50 C2-92
FMNA25J11S FMNA25J11W C/F C/F
FMNA25J5S
FMNA25J5W C2-43 C2-35
FMNA33A10S FMNA33A10W C/F C/F
(838) 28 (13) (838) 28 (13) (838) 28 (13) (838) 28 (13)
FMNA33A3S
FMNA33A3W C2-50 C2-92
FMNA33A11S FMNA33A11W C/F C/F
FMNA33A5S
FMNA33A5W C2-43 C2-35
240 7.5 1 40 1 / 2 (1029) 30 (14) 240 7.5 3 40 1 / 2 (1029) 30 (14) 480 7.5 1 40 1 / 2 (1029) 30 (14) 480 7.5 3 40 1 / 2 (1029) 30 (14)
FMNA40J10S FMNA40J10W C/F C/F
FMNA40J3S
FMNA40J3W C2-50 C2-92
FMNA40J11S FMNA40J11W C/F C/F
FMNA40J5S
FMNA40J5W C2-43 C2-35
FMNA48A10S FMNA48A10W C/F C/F
240 9.0 1 48 240 9.0 3 48 480 9.0 1 48 480 9.0 3 48
(1219) 32 (15) (1219) 32 (15) (1219) 32 (15) (1219) 32 (15)
FMNA48A3S
FMNA48A3W C2-50 C2-92
FMNA48A11S FMNA48A11W C/F C/F
FMNA48A5S FMNA64J3S
FMNA48A5W C2-43 C2-35 FMNA64J3W C2-236 C2-214
240 12.5 3 64 1 / 2 (1638) 37 (17) 480 12.5 1 64 1 / 2 (1638) 37 (17) 480 12.5 3 64 1 / 2 (1638) 37 (17)
FMNA64J11S FMNA64J11W C/F C/F
FMNA64J5S FMNA77A3S
FMNA64J5W C2-43 C2-35 FMNA77A3W C2-236 C2-214
240 15.0 3 77 480 15.0 1 77 480 15.0 3 77
(1956) 42 (19) (1956) 42 (19) (1956) 42 (19)
FMNA77A11S FMNA77A11W C/F C/F
FMNA77A5S
FMNA77A5W C2-43 C2-35
C/F - Contact factory, go to www.watlow.com/en/contact-us
Notes: • All flange bundles are designed to fit the inside diameter of the equivalent standard schedule pipe • For ANSI flange dimensions, reference chart on page 224 6 Can be rewired wye to produce 1 / 3 of the original kW and watt density (3-phase only)
243