Watlow Heater Catalog

Immersion Heaters

WATROD and FIREBAR Screw Plug Immersion Heaters

®

®

Application: Forced Air and Caustic Solutions • 2 inch NPT screw plug

General Purpose

¾ in. NPT Knockout

Thermowell 0.475 in. (12.1 mm) Dia. Elements

2 ¼ in. (57 mm) Bundle

4 ⁄ in. Dia. (117.5 mm)

• WATROD elements • Without thermostat • General purpose enclosure

13

2 ⁄ in. (65.1 mm) Cold (Ref.)

4 ¼ in. Dia. (108 mm)

"B"

• Moisture/Explosion-Resistant enclosure (suitable for use in non-classified areas only) 2" WATROD

Moisture/Explosion- Resistant

¾ in. NPT Hubs

0.475 in. (12.1 mm) Dia. Elements

Thermowell

2 ¼ in. (57 mm) Bundle

5 ⁄ in. Dia. (136.5 mm)

14

2 ⁄ in. (65.1 mm) Cold (Ref.)

4 ⁄ in. Dia. (112.7 mm)

"B"

WATCONNECT Part Number

WATCONNECT Part Number

“B” Dim. in. (mm)

Part Number

Ship Wt. lbs (kg)

Part Number 5

Ship Wt. lbs (kg)

Description Volts kW Ph

Type J T/C

Type K T/C

Type J T/C

Type K T/C

General Purpose Enclosure

Moisture/Explosion- Resistant Enclosure

120 3.0 1 17 3 / 4 (451) BHNA17N1S 240 3.0 3 17 3 / 4 (451) BHNA17N3S 480 3.0 3 17 3 / 4 (451) BHNA17N5S 120 4.5 1 25 1 / 4 (641) BHNA25E1S 240 4.5 3 25 1 / 4 (641) BHNA25E3S 480 4.5 3 25 1 / 4 (641) BHNA25E5S 240 6.0 3 32 3 / 4 (832) BHNA32N3S 480 6.0 3 32 3 / 4 (832) BHNA32N5S 240 7.5 3 40 1 / 4 (1022) BHNA40E3S 480 7.5 3 40 1 / 4 (1022) BHNA40E5S 240 9.0 3 47 3 / 4 (1213) BHNA47N3S 480 9.0 3 47 3 / 4 (1213) BHNA47N5S 240 12.5 3 64 1 / 4 (1632) BHNA64E3S 480 12.5 3 64 1 / 4 (1632) BHNA64E5S 240 15.0 3 76 3 / 4 (1950) BHNA76E3S 480 15.0 3 76 3 / 4 (1950) BHNA76E5S

23 W/in 2 6 304 SS Plug 3-Alloy 800 Elements (3.6 W/cm 2 )

C/F C/F BHNA17N1C C2-50 C2-92 BHNA17N3C C2-43 C2-35 BHNA17N5C C/F C/F BHNA25E1C C2-50 C2-92 BHNA25E3C C2-43 C2-35 BHNA25E5C C2-50 C2-92 BHNA32N3C C2-43 C2-35 BHNA32N5C C2-50 C2-92 BHNA40E3C C2-43 C2-35 BHNA40E5C C2-50 C2-92 BHNA47N3C C2-43 C2-35 BHNA47N5C C2-236 C2-214 BHNA64E3C C2-43 C2-35 BHNA64E5C C2-236 C2-214 BHNA76E3C C2-43 C2-35 BHNA76E5C

C/F C/F C3-94 C3-93 C3-116 C3-118 C/F C/F C3-94 C3-93 C3-116 C3-118 C3-94 C3-93 C3-116 C3-118 C3-94 C3-93 C3-116 C3-118 C3-94 C3-93 C3-116 C3-118 C3-114 C3-115 C3-116 C3-118 C3-114 C3-115 C3-116 C3-118

7 (4) 7 (4) 7 (4) 8 (4) 8 (4) 8 (4) 9 (4) 9 (4) 10 (5) 10 (5) 11 (5) 11 (5) 15 (7) 15 (7) 18 (9) 18 (9)

10 (5) 10 (5) 10 (5) 11 (5) 11 (5) 11 (5) 12 (6) 12 (6) 13 (6) 13 (6) 14 (7) 14 (7) 18 (9) 18 (9) 21 (10) 21 (10)

C/F - Contact factory, go to www.watlow.com/en/contact-us

Note: All screw plug bundles are designed to fit the inside diameter of the equivalent mating coupling. They will not fit into the equivalent pipe inside diameter. 5 No third party recognition 6 Can be rewired wye to produce 1 ⁄ 3 of the original kW and watt density (3-phase only)

181