Immersion Heaters

WATROD and FIREBAR Screw Plug Immersion Heaters

®

®

Application: Clean Water • 2 inch NPT screw plug • WATROD elements

¾ in. NPT Knockout

0.475 in. (12.1 mm) Dia. Elements

Thermowell

2 ¼ in. (57 mm) Bundle

5 ½ in. Dia. (140 mm)

2" WATROD

• With thermostat (DPST), Type 4, 5A or 7A Note: Higher amperage products require a pilot duty thermostat with separate power controller. Please see following pages for available heaters without thermostats. • General purpose enclosure 15

2 ⁄ in. (65.1 mm) Cold (Ref.)

6 ⁄ in. Dia. (168.3 mm)

"B"

1 ½ in. NPT Hubs

0.475 in. (12.1 mm) Dia. Elements

Thermowell

Type 4 (30 to 110°F)

Type 5A (60 to 250°F)

Type 7A (100 to 550°F)

2 ¼ in. (57 mm) Bundle

7 ⁄ in. Dia. (193.7 mm)

2" WATROD

16

WATCONNECT Part Number

WATCONNECT Part Number

WATCONNECT Part Number

“B” Dim. in. (mm)

Ship Wt. lbs (kg)

Part Number

Part Number

Part Number

Description Volts kW Ph

2 ⁄ in. (65.1 mm) Cold (Ref.)

General Purpose Enclosure

General Purpose Enclosure

General Purpose Enclosure

8 ⁄ in. Dia. (204.8 mm)

Type J T/C

Type K T/C

Type J T/C

"B" Type K T/C

Type J T/C

Type K T/C

60 W/in 2 4 304 SS Plug 2-Alloy 800 Elements (9.3 W/cm 2 ) 120/ 240 2.0 1 8 1 / 8 (206.4) 5 (3) BGN78C6S4 C/F C/F BGN78C6S5A C/F C/F BGN78C6S7A C/F C/F 240/ 480 2.0 1 8 1 / 8 (206.4) 5 (3) BGN78C7S4 C/F C/F BGN78C7S5A C/F C/F BGN78C7S7A C/F C/F 120/ 240 3.0 1 11 1 / 8 (282.6) 6 (3) BGN711C6S4 C/F C/F BGN711C6S5A C/F C/F BGN711C6S7A C/F C/F 240/ 480 3.0 1 11 1 / 8 (282.6) 6 (3) BGN711C7S4 C/F C/F BGN711C7S5A C/F C/F BGN711C7S7A C/F C/F 120/ 240 4.0 1 15 1 / 8 (384.2) 7 (4) BGN715C6S4 C/F C/F BGN715C6S5A C/F C/F BGN715C6S7A C/F C/F 120/ 240 5.0 1 18 1 / 8 (460.4) 7 (4) BGN718C6S4 C/F C/F BGN718C6S5A C/F C/F BGN718C6S7A C/F C/F 60 W/in 2 304 SS Plug 3-Alloy 800 Elements (9.3 W/cm 2 ) 240 3.0 3 8 1 / 8 (206.4) 6 (3) BHN78C3S4 C/F C/F BHN78C3S5A C/F C/F BHN78C3S7A C/F C/F 480 3.0 3 8 1 / 8 (206.4) 6 (3) BHN68C13S4 C/F C/F BHN68C13S5A C/F C/F BHN68C13S7A C/F C/F 240 4.5 3 11 1 / 8 (282.6) 7 (4) BHN711C3S4 C/F C/F BHN711C3S5A C/F C/F BHN711C3S7A C/F C/F 480 4.5 3 11 1 / 8 (282.6) 7 (4) BHN611C13S4 C/F C/F BHN611C13S5A C/F C/F BHN611C13S7A C/F C/F 240 6.0 3 15 1 / 8 (384.2) 8 (4) BHN715C3S4 C/F C/F BHN715C3S5A C/F C/F BHN715C3S7A C/F C/F 480 6.0 3 15 1 / 8 (384.2) 8 (4) BHN715C5S4 C/F C/F BHN715C5S5A C/F C/F BHN715C5S7A C/F C/F 240 7.5 3 18 1 / 8 (460.4) 8 (4) BHN718C3S4 C/F C/F BHN718C3S5A C/F C/F BHN718C3S7A C/F C/F 240 9.0 3 21 1 / 8 (536.6) 9 (4) BHN721C3S4 C/F C/F BHN721C3S5A C/F C/F BHN721C3S7A C/F C/F