Sensor and Controller Catalog

Temperature and Process

F4T

F4T Base Ordering Information

Base includes: 4.3 inch color graphical touch panel, 2 USB host, USB configuration port, standard bus, Ethernet Modbus ® TCP. SCPI protocol and backwards compatible Modbus ® for select key SERIES F4D/P/S parameters .

Part Number ①② ③

⑫ Control Algorithms

④ Application Type

⑦ Profiles & Function Blocks

⑧⑨ Communication Options

⑤ Data Logging

⑥ Power Supply Connector & Voltage, Logo

⑩⑪ Documentation, Accent Bar, Replacement Connector & Custom

Base Type T

F4

⑩⑪

Documentation, Accent Bar, Replacement Connector & Custom

Base Type

T = Touch screen

Decorated Brushed Aluminum Accent Bar Gray

Documentation DVD / QSG

Application Type

1 = Standard X = Custom options, contact factory

Blue Red None

1A = 1B = 1C = 1D = 1E = 1F = 1G = 1H =

Yes Yes Yes Yes

X

X

Data Logging and Graphic Trend Charts

X

A = None B = Graphical trend chart J = Data logging K = Data logging with encrypted files L = Data logging and graphical trend chart M = Data logging with encrypted files, graphical trend charts and batch processing with bar code data entry ① ① Must also order digit 7: Profiles option D, E or F for batch processing with bar code data entry feature to be enabled.

X

No No No No

X

X

X

X 1J = Replacement connectors only - for the model number entered XX = Contact factory, other custom-firmware, preset parameters, locked code, logo

Control Algorithms

Power Supply Connector & Voltage, Logo

Control Loop

Cascade Loop

Watlow Logo

1 = 2 = 3 = 4 = 5 = 6 = 7 = 8 = 9 = A = B = C =

1 2 3 4 0 0 1 2 3 0 1 2

0 0 0 0 0 1 1 1 1 2 2

Power Supply

Power Supply Connector

1 = 100 to 240VAC 2 = 100 to 240VAC 3 = 100 to 240VAC 4 = 100 to 240VAC

Right angle (standard) Right angle (standard)

Yes

No

Front screw Front screw

Yes

No

5 = 24 to 28VAC or VDC Right angle (standard) 6 = 24 to 28VAC or VDC Right angle (standard)

Yes

No

7 = 24 to 28VAC or VDC Front screw 8 = 24 to 28VAC or VDC Front screw

Yes

No

Profiles & Function Blocks

Profiles

Function Blocks

2 Note: Each control loop algorithm requires 1 universal or thermistor input from a flex module. Note: Each cascade loop algorithm requires 2 universal or thermistor inputs from flex modules. ⑬⑭⑮ Populated Flex Modules AAA = No populated flex modules XXX = Contact factory - Populated flex modules Note: If AAA is selected you will need to order Flex Modules (FM) next to account for input and output hardware.

40 Profiles, Battery Backup and Real-Time Clock

Basic Set

None

Set 1 Set 2

A = X B = X C = X

X

X

X

D = E = F =

X X X

X

X

X

Note: Refer to page 9 “Number of Function Blocks by Ordering Option” for quantities and types of functions blocks in each set in the F4T specification sheet on the website. ⑧⑨ Communication Options AA = Modbus ® TCP (Ethernet) A3 = EtherNet/IP™ (w/Modbus ® TCP)

1 7 2